TruEbox TFT-IV

Portable Electrical Test and Analysis System

TruEbox TFT-IV

Portable Electrical Test and Analysis System

TruEbox TFT-IV provides 4 adjustable bias voltage channels and accurately measures the drain (“D”) current in real time.
The measured current data can be transmitted via Bluetooth to a mobile app for real-time display, storage, and sharing.

TruEbox TFT-IV provides 4 adjustable bias voltage channels and accurately measures the drain (“D”) current in real time.

The measured current data can be transmitted via Bluetooth to a mobile app for real-time display, storage, and sharing.

Highlights

Real-time data display, storage, and sharing

 

  • Significantly improves measuring efficiency

Characteristic dual-gate transistor

  • Up to ±25 V adjustable excitation voltages

Wide current measurement range

  • Measurement range from pA to mA

Representative Applications

Biomedical testing

Portable electronic product development

Sports health monitoring

Transistor characterization

Product Specifications

Parameter Specification
Model LZ-TFT-IV (S)
L × W × H 114 × 105 × 37mm
Weight 400g
Charging Interface 8.4 (AC-DC Adapter)
Test Interface 4 channels of adjustable voltage output (channel “D” measures current)
Communication Bluetooth
Terminal Phone/Tablet (Android 8.0 or higher)
Current Range 10pA~1mA (both ways)
Current Accuracy • >10nA: 5%
• <10nA: 10%+100pA/current value
Voltage Output Range and Accuracy -25V~+25V, relative voltage deviation<20mV
Duration 10 hours
Data Output Rate 5 point/second
Save Original data: .CSV; Image: .PNG
Parameter Specification
Model LZ-TFT-IV (S)
L × W × H 114 × 105 × 37mm
Weight 400g
Charging Interface 8.4 (AC-DC Adapter)
Test Interface 4 channels of adjustable voltage output (channel “D” measures current)
Communication Bluetooth
Terminal Phone/Tablet (Android 8.0 or higher)
Current Range 10pA~1mA (both ways)
Current Accuracy • >10nA: 5%
• <10nA: 10%+100pA/current value
Voltage Output Range and Accuracy -25V~+25V, relative voltage deviation<20mV
Duration 10 hours
Data Output Rate 5 point/second
Save Original data: .CSV; Image: .PNG

Product Video

Measurement Series Comparison

Name TruEbox 02CM TruEbox TFT-IV
L × W × H 106 × 92 × 24mm 114 × 105 × 37mm
Weight 100g 400g
Charging Interface USB 2.0 Micro-B 8.4 (AC-DC Adapter)
Test Interface • Single: 2 channels of adjustable voltage,
1 channel of bidirectional current detection

• Multichannel: 7 channels of adjustable voltage,
8 channels of bidirectional current detection
4 channels of adjustable voltage output (channel “D” measures current)
Communication Bluetooth Bluetooth
Terminal Phone (Android 9.0 or higher) Phone/Tablet (Android 8.0 or higher)
Current Range ±(1nA~1mA) 10pA~1mA (both ways)
Current Accuracy • ±(1nA~10nA), Error range: 1%+1nA/current value
• ±(10nA~1mA), Error range: 1.6%+1nA/current value"
• >10nA: 5%
• <10nA: 10%+100pA/current value
Voltage Output Range and Accuracy -1.66V~+1.54V (Based on the current measuring terminal voltage),
Voltage error: <10mV
-25V~+25V, relative voltage deviation<20mV
Duration >5 hours 10 hours
Data Output Rate • Single: 50 point/second/channel
• Multichannel: 5 point/second/channel
5 point/second
Save Original data: .CSV; Image: .PNG Original data: .CSV; Image: .PNG

(手机版)挚盒TFT-IV--同系列产品对比(英文版)

Name TruEbox 02CM TruEbox TFT-IV
L × W × H 106 × 92 × 24mm 114 × 105 × 37mm
Weight 100g 400g
Charging Interface USB 2.0 Micro-B 8.4 (AC-DC Adapter)
Test Interface • Single: 2 channels of adjustable voltage,
1 channel of bidirectional current detection

• Multichannel: 7 channels of adjustable voltage,
8 channels of bidirectional current detection
4 channels of adjustable voltage output (channel “D” measures current)
Communication Bluetooth Bluetooth
Terminal Phone (Android 9.0 or higher) Phone/Tablet (Android 8.0 or higher)
Current Range ±(1nA~1mA) 10pA~1mA (both ways)
Current Accuracy • ±(1nA~10nA), Error range: 1%+1nA/current value
• ±(10nA~1mA), Error range: 1.6%+1nA/current value"
• >10nA: 5%
• <10nA: 10%+100pA/current value
Voltage Output Range and Accuracy -1.66V~+1.54V (Based on the current measuring terminal voltage),
Voltage error: <10mV
-25V~+25V, relative voltage deviation<20mV
Duration >5 hours 10 hours
Data Output Rate • Single: 50 point/second/channel
• Multichannel: 5 point/second/channel
5 point/second
Save Original data: .CSV; Image: .PNG Original data: .CSV; Image: .PNG

Downloads

TruEbox TFT-IV_User Guide

0.37MB

TruEbox TFT-IV_APP

5.67MB

Contact

Contact Us

info@linkzill.com

Dr. Kang Kang

Partner & CBio

Dr. Kang received his Ph.D. in Bioinformatics and Systems Biology from the University of Hong Kong in 2018, then became a scientific co-worker of the Leibniz Association (Leibniz-HKI) and a visiting scientist at the Novo Nordisk Foundation Center for Biosustainability (DTU Biosustain) at the Technical University of Denmark. He was a scientist at BGI-Shenzhen and co-founded the synthetic biology research group. He was a senior bioinformatics engineer and brand advisor at WeGene. In 2021, Kang joined Biosysen Limited as a co-founder and served as Chief Informatics Scientist. He is also an advisor and author of the biotech media "Regenesis". He has been dedicated to the R&D and industrialization of OMICs technologies, high-throughput technologies, and synthetic biology for over 10 years. He joined LinkZill in March 2023, responsible for semiconductor life science tools and product planning.