TruEbox 02CM

Portable Precision Current Measurement System

TruEbox 02CM

Portable Precision Current Measurement System

TruEbox 02CM can provide multichannel (seven) bias voltages and measure multichannel (eight) currents.
The device can measure real-time, accurate current, and send it to the mobile APP via Bluetooth to realize real-time data display, storage, and sharing.

TruEbox 02CM can provide multichannel (seven) bias voltages and measure multichannel (eight) currents.

The device can measure real-time, accurate current, and send it to the mobile APP via Bluetooth to realize real-time data display, storage, and sharing.

Highlights

Real-time data display, storage, and sharing

  • Significantly improves measuring efficiency

Multi-channel testing

  • Up to 8 channels current readout

Multi-channel adjustable bias voltages

  • Up to 7 DC bias voltages providing

Representative Applications

Biomedical testing

Portable electronic product development

Biomedical testing

Product Specifications

Parameter Specification
Model LZ-02ACM (M)
L × W × H 106 × 92 × 24mm
Weight 100g
Charging interface USB 2.0 Micro-B
Test interface • Single: 2 channels of adjustable voltage,
1 channel of bidirectional current detection

• Multichannel: 7 channels of adjustable voltage,
8 channels of bidirectional current detection
Communication Bluetooth
Terminal Phone/Tablet (Android 9.0 or higher)
Current range ±(1nA~1mA)
Current measurement accuracy • ±(1nA~10nA), Error range: 1%+1nA/current value

• ±(10nA~1mA), Error range: 1.6%+1nA/current value
Voltage output range and accuracy -1.66V~+1.54V (Based on the current measuring terminal voltage),
Voltage error: <10mV
Duration >5 hours
Data output rate Single: 50 point/second/channel;
Multichannel: 5 point/second/channel;
Save Original data: .CSV; Image: .PNG
Parameter Specification
Model LZ-02ACM (M)
L × W × H 106 × 92 × 24mm
Weight 100g
Charging interface USB 2.0 Micro-B
Test interface • Single: 2 channels of adjustable voltage,
1 channel of bidirectional current detection

• Multichannel: 7 channels of adjustable voltage,
8 channels of bidirectional current detection
Communication Bluetooth
Terminal Phone/Tablet (Android 9.0 or higher)
Current range ±(1nA~1mA)
Current measurement accuracy • ±(1nA~10nA), Error range: 1%+1nA/current value

• ±(10nA~1mA), Error range: 1.6%+1nA/current value
Voltage output range and accuracy -1.66V~+1.54V (Based on the current measuring terminal voltage),
Voltage error: <10mV
Duration >5 hours
Data output rate Single: 50 point/second/channel;
Multichannel: 5 point/second/channel;
Save Original data: .CSV; Image: .PNG

Product Video

Measurement Series Comparison

Name TruEbox 02CM TruEbox TFT-IV
L × W × H 106 × 92 × 24mm 114 × 105 × 37mm
Weight 100g 400g
Charging Interface USB 2.0 Micro-B 8.4 (AC-DC Adapter)
Test Interface • Single: 2 channels of adjustable voltage,
1 channel of bidirectional current detection

• Multichannel: 7 channels of adjustable voltage,
8 channels of bidirectional current detection
4 channels of adjustable voltage output (channel “D” measures current)
Communication Bluetooth Bluetooth
Terminal Phone (Android 9.0 or higher) Phone/Tablet (Android 8.0 or higher)
Current Range ±(1nA~1mA) 10pA~1mA (both ways)
Current Accuracy • ±(1nA~10nA), Error range: 1%+1nA/current value
• ±(10nA~1mA), Error range: 1.6%+1nA/current value"
• >10nA: 5%
• <10nA: 10%+100pA/current value
Voltage Output Range and Accuracy -1.66V~+1.54V (Based on the current measuring terminal voltage),
Voltage error: <10mV
-25V~+25V, relative voltage deviation<20mV
Duration >5 hours 10 hours
Data Output Rate • Single: 50 point/second/channel
• Multichannel: 5 point/second/channel
5 point/second
Save Original data: .CSV; Image: .PNG Original data: .CSV; Image: .PNG

(手机版)挚盒02CM--同系列产品对比(英文版)

Name TruEbox 02CM TruEbox TFT-IV
L × W × H 106 × 92 × 24mm 114 × 105 × 37mm
Weight 100g 400g
Charging Interface USB 2.0 Micro-B 8.4 (AC-DC Adapter)
Test Interface • Single: 2 channels of adjustable voltage,
1 channel of bidirectional current detection

• Multichannel: 7 channels of adjustable voltage,
8 channels of bidirectional current detection
4 channels of adjustable voltage output (channel “D” measures current)
Communication Bluetooth Bluetooth
Terminal Phone (Android 9.0 or higher) Phone/Tablet (Android 8.0 or higher)
Current Range ±(1nA~1mA) 10pA~1mA (both ways)
Current Accuracy • ±(1nA~10nA), Error range: 1%+1nA/current value
• ±(10nA~1mA), Error range: 1.6%+1nA/current value"
• >10nA: 5%
• <10nA: 10%+100pA/current value
Voltage Output Range and Accuracy -1.66V~+1.54V (Based on the current measuring terminal voltage),
Voltage error: <10mV
-25V~+25V, relative voltage deviation<20mV
Duration >5 hours 10 hours
Data Output Rate • Single: 50 point/second/channel
• Multichannel: 5 point/second/channel
5 point/second
Save Original data: .CSV; Image: .PNG Original data: .CSV; Image: .PNG

Downloads

TruEbox 02CM_User Guide

0.42MB

TruEbox 02CM_APP

4.37MB

Contact

Contact Us

info@linkzill.com

Dr. Kang Kang

Partner & CBio

Dr. Kang received his Ph.D. in Bioinformatics and Systems Biology from the University of Hong Kong in 2018, then became a scientific co-worker of the Leibniz Association (Leibniz-HKI) and a visiting scientist at the Novo Nordisk Foundation Center for Biosustainability (DTU Biosustain) at the Technical University of Denmark. He was a scientist at BGI-Shenzhen and co-founded the synthetic biology research group. He was a senior bioinformatics engineer and brand advisor at WeGene. In 2021, Kang joined Biosysen Limited as a co-founder and served as Chief Informatics Scientist. He is also an advisor and author of the biotech media "Regenesis". He has been dedicated to the R&D and industrialization of OMICs technologies, high-throughput technologies, and synthetic biology for over 10 years. He joined LinkZill in March 2023, responsible for semiconductor life science tools and product planning.