TruEbox TFT-IV provides 4 adjustable bias voltage channels and accurately measures the drain (“D”) current in real time. 
The measured current data can be transmitted via Bluetooth to a mobile app for real-time display, storage, and sharing.
				TruEbox TFT-IV provides 4 adjustable bias voltage channels and accurately measures the drain (“D”) current in real time. 
The measured current data can be transmitted via Bluetooth to a mobile app for real-time display, storage, and sharing.
				Highlights
Real-time data display, storage, and sharing
- Significantly improves measuring efficiency
 
Characteristic dual-gate transistor
- Up to ±25 V adjustable excitation voltages
 
Wide current measurement range
- Measurement range from pA to mA
 
Representative Applications
															Biomedical testing
															Portable electronic product development
															Sports health monitoring
															Transistor characterization
Product Specifications
| Parameter | Specification | 
| Model | LZ-TFT-IV (S) | 
| L × W × H | 114 × 105 × 37mm | 
| Weight | 400g | 
| Charging Interface | 8.4 (AC-DC Adapter) | 
| Test Interface | 4 channels of adjustable voltage output (channel “D” measures current) | 
| Communication | Bluetooth | 
| Terminal | Phone/Tablet (Android 8.0 or higher) | 
| Current Range | 10pA~1mA (both ways) | 
| Current Accuracy | 
                                • >10nA: 5% • <10nA: 10%+100pA/current value  | 
                                        
| Voltage Output Range and Accuracy | -25V~+25V, relative voltage deviation<20mV | 
| Duration | 10 hours | 
| Data Output Rate | 5 point/second | 
| Save | Original data: .CSV; Image: .PNG | 
| Parameter | Specification | 
| Model | LZ-TFT-IV (S) | 
| L × W × H | 114 × 105 × 37mm | 
| Weight | 400g | 
| Charging Interface | 8.4 (AC-DC Adapter) | 
| Test Interface | 4 channels of adjustable voltage output (channel “D” measures current) | 
| Communication | Bluetooth | 
| Terminal | Phone/Tablet (Android 8.0 or higher) | 
| Current Range | 10pA~1mA (both ways) | 
| Current Accuracy | 
                                • >10nA: 5% • <10nA: 10%+100pA/current value  | 
                                        
| Voltage Output Range and Accuracy | -25V~+25V, relative voltage deviation<20mV | 
| Duration | 10 hours | 
| Data Output Rate | 5 point/second | 
| Save | Original data: .CSV; Image: .PNG | 
Product Video
Measurement Series Comparison
                                                  | 
                                            
                                                  | 
                                        |
| Name | TruEbox 02CM | TruEbox TFT-IV | 
| L × W × H | 106 × 92 × 24mm | 114 × 105 × 37mm | 
| Weight | 100g | 400g | 
| Charging Interface | USB 2.0 Micro-B | 8.4 (AC-DC Adapter) | 
| Test Interface | 
                                • Single:   2 channels of adjustable voltage, 1 channel of bidirectional current detection • Multichannel: 7 channels of adjustable voltage, 8 channels of bidirectional current detection  | 
                                            4 channels of adjustable voltage output (channel “D” measures current) | 
| Communication | Bluetooth | Bluetooth | 
| Terminal | Phone (Android 9.0 or higher) | Phone/Tablet (Android 8.0 or higher) | 
| Current Range | ±(1nA~1mA) | 10pA~1mA (both ways) | 
| Current Accuracy | 
                                • ±(1nA~10nA), Error range: 1%+1nA/current value • ±(10nA~1mA), Error range: 1.6%+1nA/current value"  | 
                                            
                                • >10nA: 5% • <10nA: 10%+100pA/current value  | 
                                        
| Voltage Output Range and Accuracy | 
                                -1.66V~+1.54V (Based on the current measuring terminal voltage),  Voltage error: <10mV  | 
                                            -25V~+25V, relative voltage deviation<20mV | 
| Duration | >5 hours | 10 hours | 
| Data Output Rate | 
                                • Single: 50 point/second/channel • Multichannel: 5 point/second/channel  | 
                                            5 point/second | 
| Save | Original data: .CSV; Image: .PNG | Original data: .CSV; Image: .PNG | 
(手机版)挚盒TFT-IV--同系列产品对比(英文版)
                                                  | 
                                            
                                                  | 
                                        |
| Name | TruEbox 02CM | TruEbox TFT-IV | 
| L × W × H | 106 × 92 × 24mm | 114 × 105 × 37mm | 
| Weight | 100g | 400g | 
| Charging Interface | USB 2.0 Micro-B | 8.4 (AC-DC Adapter) | 
| Test Interface | 
                                • Single:   2 channels of adjustable voltage, 1 channel of bidirectional current detection • Multichannel: 7 channels of adjustable voltage, 8 channels of bidirectional current detection  | 
                                            4 channels of adjustable voltage output (channel “D” measures current) | 
| Communication | Bluetooth | Bluetooth | 
| Terminal | Phone (Android 9.0 or higher) | Phone/Tablet (Android 8.0 or higher) | 
| Current Range | ±(1nA~1mA) | 10pA~1mA (both ways) | 
| Current Accuracy | 
                                • ±(1nA~10nA), Error range: 1%+1nA/current value • ±(10nA~1mA), Error range: 1.6%+1nA/current value"  | 
                                            
                                • >10nA: 5% • <10nA: 10%+100pA/current value  | 
                                        
| Voltage Output Range and Accuracy | 
                                -1.66V~+1.54V (Based on the current measuring terminal voltage),  Voltage error: <10mV  | 
                                            -25V~+25V, relative voltage deviation<20mV | 
| Duration | >5 hours | 10 hours | 
| Data Output Rate | 
                                • Single: 50 point/second/channel • Multichannel: 5 point/second/channel  | 
                                            5 point/second | 
| Save | Original data: .CSV; Image: .PNG | Original data: .CSV; Image: .PNG |